268 / 2019-11-15 22:38:56
Research on the analysis of the eddy current response to the lay length of the wire rope
Wire rope, Lay length, Eddy current testing, Finite element analysis
摘要待审
少妮 焦 / 太原理工大学
晓娟 贾 / 河北工程大学
腾宇 李 / 太原理工大学
书奎 金 / 太原理工大学
子明 寇 / 太原理工大学
吴 娟 / 太原理工大学
彦飞 寇 / 中北大学
The lay length is one of the important parameters for the wire rope and its detection can indirectly characterize its stress and surface damage state. In order to eliminate the disadvantages of measuring the lay length by the image recognition method and the magnetic flux leakage method (MFL), the eddy current testing (ECT) method for the measurement of lay length is proposed in this paper. The eddy current (EC) response to the wire rope is simulated. The EC on the surface of the strand below the pancake coil forms a vortex, and the distribution of the EC on the curved surfaces on both sides of the strand is symmetrical. The spacing between the adjacent peaks or troughs of the scanning signal is the distance between the adjacent strands, and the number of peaks or troughs of the scanning signal in a range of the lay length is related to the number of strands of the wire rope. Finally, the experimental validation is performed. The relative error of the lay length of the wire rope assessed by the EC method is less than 0.28%.