51 / 2019-03-08 22:37:23
Environmentally-Assisted Cracking (EAC) resistance in martensite-based stainless steel OCTG materials (high-temperature load-applied autoclave test)
全文待审
This paper report Environmentally-Assisted Cracking (EAC) resistance, which many engineers may have misunderstood as SCC (Stress Corrosion Cracking), in martensite-based stainless steel OCTG materials in sour condition at room temperature (RT) to 200°C, by applying stress on Four Point Bent Beam (FPBB) inside autoclave.
As a conventional concept, SCC-susceptible temperature range for duplex stainless steel has already been recognized widely, and many engineers often pay attention to 80 to 100°C in material selection duplex stainless steel, and they often check SCC resistance by using autoclave. In this paper, EAC resistance (autoclave test) is targeted for martensitic stainless steel OCTG materials and discussed whether similar SCC-susceptible range exists or not.
Through the comprehensive testing by using FPBB specimens under the conditions of (1)100%AYS@in-situ, (2)saturated gas environment of 5MPa CO2 gas and 0.01MPa H2S gas and (3)the combined environments of both “pH3.0 to pH4.0” and “temperature of 24 to 200°C”, EAC resistance (domain map) for HP2-13CR-110 (13Cr-5Ni-2Mo-based), UHP-15CR-125 (15-6-3-Cu-based), and UHP-17CR-110 (17-4.5-3-Cu-W-based) are reported. The following conclusions are drawn in this paper: (a) tested Martensite-based OCTG materials do not have specific SCC-susceptible temperature range of 80 to 100°C. (b)EAC in martensitic stainless steel is not based on SCC (anodic: Fe-dissolution), but on SSC (cathodic: Hydrogen embrittlement). (c)Domain map (pH-temperature map) in EAC is restricted by either SSC or corrosion rate. (d)As interpretation for SSC resistance, when FPBB test starts to be performed at from RT to higher temperature and then no-cracking is observed at a certain temperature, no-cracking keeps going on at higher temperature, from then on. (e)As interpretation for general corrosion rate, as temperature goes down, general corrosion gets milder. When general corrosion test starts to be performed at from higher temperature to RT and then general corrosion rate is below the criteria at a certain temperature, corrosion rate keeps lower than the criteria.
重要日期
  • 会议日期

    05月22日

    2019

    05月24日

    2019

  • 04月30日 2019

    初稿截稿日期

  • 05月24日 2019

    注册截止日期

主办单位
中国石油集团工程材料研究院有限公司
承办单位
中国石油集团石油管工程技术研究院 (TGRI)
联系方式
历届会议
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询