Detector layout optimization for in-pipe source term inversion based on the response matrix
编号:15 访问权限:仅限参会人 更新:2026-10-21 21:46:31 浏览:3次 口头报告

报告开始:暂无开始时间(Asia/Shanghai)

报告时间:暂无持续时间

所在会场:[暂无会议] [暂无会议段]

演示文件

提示:该报告下的文件权限为仅限参会人,您尚未登录,暂时无法查看。

摘要
 Characterizing radioactive deposits in process piping is important for nuclear facility decommissioning and radioactive waste management, yet direct measurement of internal source distributions is often impractical. This study develops a constrained detector-placement method for reconstructing the relative strengths of multiple source regions from limited external measurements. Without access to the held-out source distributions used for evaluation, detector selection relies only on OpenMC response matrices, their Monte Carlo statistical uncertainties, and prespecified installation constraints. The method preserves information in the weakest observable direction while favoring layouts with greater overall information content. It is evaluated for straight, single-bend, and triple-bend pipe geometries, each containing seven source regions emitting monoenergetic 661.657 keV photons from Cs-137. Two independently generated Monte Carlo response sets are used separately for detector selection and reconstruction, and for observation generation and performance evaluation. This separation reduces the risk of overly optimistic evaluation associated with using an identical response matrix for both data generation and inversion. Reconstruction is performed using weighted non-negative least squares for 250 held-out source distributions, with 100 independent Poisson realizations for each distribution. For performance evaluation, the simulated measurements are scaled to a reference count level of 10,000, with background counts set to 20% of this level. Compared with engineering-uniform layouts, the proposed layouts reduce the mean relative L2 reconstruction error by 22.59%, 5.44%, and 52.21% for the straight, single-bend, and triple-bend geometries, respectively. The benefit depends on both geometry and source distribution, with the largest improvement observed in the triple-bend geometry. In the straight pipe, comparisons with layouts based on either information criterion alone are inconclusive, while the single- and double-hotspot families in the single-bend geometry show no stable improvement over the engineering-uniform layout. These results indicate that response matrices and their statistical uncertainties can guide detector placement without using the evaluation source distributions.
关键词
Source-term inversion; Detector placement; Response matrix; OpenMC; Nuclear decommissioning
报告人
Xiaochang Zheng
PhD Student Harbin Engineering University

稿件作者
Xiaochang Zheng Harbin Engineering University
Yongkuo Liu Harbin Engineering University
Jifeng Hu Harbin Engineering University
Youwu Xu Harbin Engineering University
发表评论
验证码 看不清楚,更换一张
全部评论
重要日期
  • 会议日期

    10月30日

    2026

    至

    11月01日

    2026

  • 09月30日 2026

    初稿截稿日期

主办单位
Harbin Engineering University
State Key Laboratory of Marine Thermal Energy and Power
Heilongjiang Nuclear Society
移动端
在手机上打开
小程序
打开微信小程序
客服
扫码或点此咨询