matching resistance of high voltage cables is also used as a divider to improve the measurement range of insulators from 180-300kV to 30-300kV. Paralleling with the insulator is a resistance voltage probe(RVP) used to measure the sample voltage which would evaporate while flashover is forming.
  on both nylon and XLPS cylindrical insulation materials with the thickness of 10mm. Hundreds of data is to be processed and analysed. XLPS insulators show stabler properties under triple-pulses. Nervertheless, laid aside for a period of time, mostly one night, nylon insulators could undergo a better voltage. Generally, if the preceding pulse causes flashover then subsequent pulses would definitely cause the same breakdown, and the conditioned voltage(Uco) of each three pulse differs a lot and decreases progressively, which is not noticed in former experiment results. We suppose it is connected to the build time of penetrating conducting pathway and charge transport mechanism. It is significant to studying insulating technology in pulsed power.                06月05日