39 / 2021-06-23 03:41:12
The Inter-turns Short Circuit Fault Detection based on External Leakage Flux Sensing and VMD-HHT Analytical Method for DFIG
终稿
Shouwang Zhao / Xi'an Jiaotong University
Yu Chen / Xi'an Jiaotong University
Attiq Ur Rehman / Xi'an Jiaotong University
Feng Liang / Xi'an Jiaotong University
Shuang Wang / Xi'an Jiaotong University
Wei Deng / Xi'an Thermal Power Research Institude Co.Ltd
Yong Zhao / Xi'an Thermal Power Research Institude Co.Ltd
Yong Ma / Xi'an Thermal Power Research Institude Co.Ltd
Yonghong Cheng / Xi'an Jiaotong University
The monitoring and analysis of the motor external leakage flux can experience various kinds of faults in stators and rotors, such as inter-turns short circuit fault, stator insulation failure, bearing fault, eccentricity and broken rotor bar/end-ring, etc., has been gaining more and more attention and research, due to its non-invasive, comparable to motor current signature analysis, and also more straightforward structure and lower cost, has been a modern and future trend as significant research work. However, for high-power wind turbines, especially, Doubly Fed Induction Generator (DFIG) is widely used at present, due to the harsh environment located, the external leakage flux signals of the generators are easily submerged by the strong noise background, which limits the practical engineering application of this technology. Aiming at the inter-turn short circuit fault of DFIG, this paper proposes a method for inter-turn short circuit fault feature extraction based on Variational Mode Decomposition and Hilbert-Huang Transform (VMD-HHT) method for the external magnetic flux leakage (MFL) of the generator. Through VMD decomposition of inter-turn short circuit fault signals, a series of intrinsic mode function (IMF) components are obtained. A comprehensive evaluation criterion of correlativity, kurtosis, and multi-scale permutation entropy was used to select the best IMF components with apparent features. The selected IMF components were analyzed by HHT. The fault features and the corresponding fault phenomenon were extracted by the VMD-HHT method. The experimental results show that the diagnosis method based on the VMD-HHT method can effectively extract the weak feature information from the external MFL signals and realize the fault feature extraction of inter-turn short circuit fault.
重要日期
  • 会议日期

    10月21日

    2021

    10月23日

    2021

  • 10月26日 2021

    注册截止日期

主办单位
Southeast University, China
移动端
在手机上打开
小程序
打开微信小程序
客服