467 / 2018-12-30 17:50:05
Influence of Flow Arrangement Pattern on Thermal Performance of Tri-sector Rotary Regenerative Air Pre-heater and Deposition Rule for Ammonium Bisulfate
Rotary regenerative air preheater; Parallel-flow–counter-flow arrangement pattern; Thermal performance; Deposition of ammonium bisulfate
全文录用
Xun Chen / State Grid Hunan Electric Power Co., Ltd. Research Institute
We analyzed rules for temperature field distribution of fluids and metal elements, and examined the deposition area of ammonium bisulfate (ABS) of a rotary air preheater based on the finite-difference method under the parallel-flow–counter-flow arrangement patterns for flue gas, secondary air, and primary air. The result shows that, when the flow arrangement pattern is changed from counter flow to a mixed pattern for parallel and counter flow, distributions for the fluid and metal temperature field change significantly. By taking advantage of the parallel-flow–counter-flow arrangement method, one can effectively ensure that the deposition area of ammonium bisulfate is fully within the cold-end scope, with relatively good transparency for soot blowing.